![Replacing the electromagnet of Hiblow HP 10-50 Series 1 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet.png)
![Replacing the electromagnet of Hiblow HP 10-50 Series 2 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-1.png)
Step 1
REMOVING THE ELECTROMAGNET
Cut the wire from the terminals on the electromagnet with nippers.
• It is recommended that you make a note of the wiring
![Replacing the electromagnet of Hiblow HP 10-50 Series 3 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-2.png)
Step 2
Remove the nuts with the box driver. (7mm wrench.)
![Replacing the electromagnet of Hiblow HP 10-50 Series 4 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-3.png)
Step 3
Pull out electromagnets from the pump body.
![Replacing the electromagnet of Hiblow HP 10-50 Series 5 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-4.png)
Step 4
FITTING THE ELECTROMAGNET
Secure the electromagnets to the body by the nuts. Use the box driver. (7mm wrench)
![Replacing the electromagnet of Hiblow HP 10-50 Series 6 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-5.png)
Step 5
Tie the wires in a bundle with a silicon tube. Connect the wires to the terminals.
![Replacing the electromagnet of Hiblow HP 10-50 Series 7 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-6.png)
Step 6
Solder the wires to the terminals. The wire requires a soldered connection.
![Replacing the electromagnet of Hiblow HP 10-50 Series 8 Replacing the electromagnet of Hiblow HP 10-50 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-1050-Replacing-the-electromagnet-7.png)
Step 7
This completes the electromagnet replacement procedure.