Step 1

Cut the wires from the terminals on the electromagnet with the nippers.
It is recommended that you make a note of the wiring.

Replacing the chamber block of Hiblow GJ-L Series

Step 2

A status indication. (Same lead wires and connections are cut.)

Replacing the chamber block of Hiblow GJ-L Series

Step 3

Remove the nuts with the 7mm wrench.

Replacing the chamber block of Hiblow GJ-L Series

Step 4

Pull out the electromagnets from the body.

Replacing the chamber block of Hiblow GJ-L Series

Step 5

The state of the new electromagnets. One of the electromagnets has the soldered terminals. Strip off the coating each of the wires. (5mm from the end.)

Replacing the chamber block of Hiblow GJ-L Series

Step 6

Secure the electromagnets to the body by the nuts. Use the 7mm wrench. Tie the wires in a bundle with a silicon tube.

Replacing the chamber block of Hiblow GJ-L Series

Step 7

Connect the wires to the terminals.

Replacing the chamber block of Hiblow GJ-L Series

Step 8

Solder the wires to the terminals. The wire requires a soldered connection. Touch the terminals to promote solderability from under side of the terminal with a soldering iron. This completes the electromagnet replacement procedure. Please go on the next operations.