Replacing the electromagnet of Hiblow HP -100/120

Replacing the electromagnet of Hiblow HP -100/120
Replacing the electromagnet of Hiblow HP -100/120

Step 1

REMOVAL OF ELECTROMAGNET
Cut the wire from the terminals on electromagnets with nippers.
It is recommended that you make a note of the wiring

Replacing the electromagnet of Hiblow HP -100/120

Step 2

Undo the frame screws and remove the SP switch

Replacing the electromagnet of Hiblow HP -100/120

Step 3

Remove the nuts with the box driver. (8mm wrench) 

Pull out the electromagnets from the pump body.

Replacing the electromagnet of Hiblow HP -100/120

Step 4

FITTING THE ELECTROMAGNET
Secure the electromagnets to the body by the nuts. 

Use the box driver. (wrench)

Replacing the electromagnet of Hiblow HP -100/120

Step 5

Secure the SP switch to the frame by the screws.

• Be careful of the direction.

Replacing the electromagnet of Hiblow HP -100/120

Step 6


Tie the wire in a bundle with a silicon tube. Strip off the coating each of the wire. (7mm from the end) Connect the wire to the terminals. Solder the wires to the terminals. The wire requires a soldered connection.

Replacing the electromagnet of Hiblow HP -100/120

Step 7

This completes the electromagnet replacement procedure.