![Replacing the electromagnet of Hiblow HP 60-80 Series 1 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet.png)
![Replacing the electromagnet of Hiblow HP 60-80 Series 2 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-1.png)
Step 1
REMOVAL OF ELECTROMAGNET
Cut the wire from terminals on the electromagnets with nippers.
It is recommended that you make a note of the wiring.
![Replacing the electromagnet of Hiblow HP 60-80 Series 3 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-2.png)
Step 2
Undo the frame screws and remove the SP switch.
![Replacing the electromagnet of Hiblow HP 60-80 Series 4 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-3.png)
Step 3
Remove the mounting nuts with the box driver. (7mm wrench)Â
Pull out the electromagnets from the pump body.
![Replacing the electromagnet of Hiblow HP 60-80 Series 5 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-4.png)
Step 4
FITTING THE ELECTROMAGNET
Secure the electromagnets to the body by the nuts.
Use the boxdriver. (wrench)
![Replacing the electromagnet of Hiblow HP 60-80 Series 6 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-5.png)
Step 5
Secure the SP switch to the frame by the screws.
• Be careful of the direction.
![Replacing the electromagnet of Hiblow HP 60-80 Series 7 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-6.png)
Step 6
Tie the wires in a bundle with a silicon tube. Strip off the coating each of the wires. (7mm from the end)
Connect the wires to the terminals.
The wire requires a soldered connection.
![Replacing the electromagnet of Hiblow HP 60-80 Series 8 Replacing the electromagnet of Hiblow HP 60-80 Series](https://www.pumpular.com/wp-content/uploads/2022/10/HP-6080-Replacing-the-electromagnet-7.png)
Step 7
This completes the electromagnet replacement procedure.