Replacing the electromagnet of Hiblow GJ-L Series

Replacing the chamber block of Hiblow GJ-L Series

Step 1 Cut the wires from the terminals on the electromagnet with the nippers. It is recommended that you make a note of the wiring. Step 2 A status indication. (Same lead wires and connections are cut.) Step 3 Remove the nuts with the 7mm wrench. Step 4 Pull out the electromagnets from the body. […]

Replacing the chamber block of Hiblow GJ-L Series

Replacing the chamber block of Hiblow GJ-L Series

Step 1 Remove the knob bolt. (or truss screw) Step 2 Remove the filter cover and the filter. Step 3 Remove the bolts from the four corners. Turn the pump up side down. Use 8.Omm each side wrench. Step 4 According to the photo, use a screwdriver to pry open upper and lower housing. If […]

×